Publisher: New York Springer 2019Edition: Vol.100(4), Dec.Description: 535-546p.Subject(s): Construction Engineering and Management (CEM)Online resources: Click here In: Journal of the institution of engineers (India): Series ASummary: In recent years, strengthening and enhancement of durability of concrete columns have increased significantly in the medium-rise or high-rise buildings across the globe. Strengthening of a concrete column may lead to the section composite as it uses encasing techniques. In this presentation, instead of post-strengthening of columns, the authors wish to utilize the advantage of composite sectional properties to enhance the durability of the concrete column. In general, steel tubes are extensively used for such purpose in the past decades, as design guidelines are available in the literature and various codes of practice. In the present investigation, reinforced concrete-filled unplasticized polyvinyl chloride pipes are taken up as composite column sections to study its structural behavior, viz. failure pattern, bond strength, confinement, and flexural behavior as it simultaneously improves the response with better confinement along with protecting the same from adverse environmental hazards, as well as to study its effectiveness as low-cost housing. Seventy-two confined (filled) column and 27 unconfined column specimens were tested to investigate the effects of various parameters on the ultimate load-carrying capacity and the load–deformation behavior of the columns. All the specimens are found with localized failure. Concrete column exhibits sudden failure when displacement reached the range of 3.4–6.7 mm. While for the confined reinforced concrete column, it reaches 22.3 mm without sudden failure while retaining its integrity. Detail study shows that ductility of specimens increases with the increase in pipe thickness. Finally utilizing the extensive experimental data and with the help of EUROCODE-4, a mathematical model based on response surface methodology has been proposed for the purpose of predicting the load-carrying capacity of the confined as well as unconfined RC stub columns.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG)
Archieval Section
Not for loan 2021042
Total holds: 0

In recent years, strengthening and enhancement of durability of concrete columns have increased significantly in the medium-rise or high-rise buildings across the globe. Strengthening of a concrete column may lead to the section composite as it uses encasing techniques. In this presentation, instead of post-strengthening of columns, the authors wish to utilize the advantage of composite sectional properties to enhance the durability of the concrete column. In general, steel tubes are extensively used for such purpose in the past decades, as design guidelines are available in the literature and various codes of practice. In the present investigation, reinforced concrete-filled unplasticized polyvinyl chloride pipes are taken up as composite column sections to study its structural behavior, viz. failure pattern, bond strength, confinement, and flexural behavior as it simultaneously improves the response with better confinement along with protecting the same from adverse environmental hazards, as well as to study its effectiveness as low-cost housing. Seventy-two confined (filled) column and 27 unconfined column specimens were tested to investigate the effects of various parameters on the ultimate load-carrying capacity and the load–deformation behavior of the columns. All the specimens are found with localized failure. Concrete column exhibits sudden failure when displacement reached the range of 3.4–6.7 mm. While for the confined reinforced concrete column, it reaches 22.3 mm without sudden failure while retaining its integrity. Detail study shows that ductility of specimens increases with the increase in pipe thickness. Finally utilizing the extensive experimental data and with the help of EUROCODE-4, a mathematical model based on response surface methodology has been proposed for the purpose of predicting the load-carrying capacity of the confined as well as unconfined RC stub columns.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha